NTEC

M/02 · KURIN · Cooling circuit care

Mold Channel Cleaning Machine

Cleaner channels, better cooling, longer mold life.

M/02K-series · K2-15C to K8-55C1.5 – 5.5 kW pump
The problem

Blocked channels make every cycle slower.

Rust and scale choke mold cooling channels, lengthening cycle time and causing defects. Cleaning them by hand means taking the mold apart.

How it works

Bursting bubbles break the scale loose.

Air and water mixed at high pressure create bursting bubbles that break scale loose. Plug and play and fully automatic: no disassembly, no operator watching. Cleaning time is set from 30 minutes to 4 hours.

Step 01

Connect

Hook the mold’s cooling circuits to the machine — no disassembly.

Step 02

Pulse clean

High-pressure air and water bubbles burst against the scale, reversing direction every 5 minutes.

Step 03

Test and report

Leak and flow tests run automatically and a cleaning report is saved per mold.

M/02 · How it works
Cleaning cycle

Eight automatic steps.

Direction reverses every 5 minutes so scale is attacked from both sides.

01 / 08

Before clean

Functions

More than a flush.

0.2–0.65 MPa

Bi-directional pulse cleaning

Filter 0.2–0.65 MPa, air 0.4–0.8 MPa.

8.5 bar

Leak and blockage test

Tested at 8.5 bar with a ±0.01 bar sensor.

Ultrasonic

Flow measurement

Keyence ultrasonic flow meter.

Auto

Automatic water recovery

Drains the channels to prevent rust.

Per mold

Cleaning report per mold

Every cycle is recorded.

Data and reporting

Proof of every clean.

Each cycle produces a report you can file against the mold — so maintenance is measured, not guessed.

Proof of every clean.KURIN · M/02
Mold name
—
Date
—
Cleaning duration
—
Flow rate before
— L/min
Flow rate after
— L/min
Before
After

Report fields shown; a sample screenshot will be added.

Benefits

Cleaner channels, better cooling, longer mold life.

01

Better cooling efficiency

Open channels carry heat out faster.

02

Lower maintenance cost

Less downtime, no disassembly.

03

Longer mold life

Rust and scale removed before damage spreads.

04

Higher productivity

Shorter, more stable cycle times and better part quality.

05

Environmentally friendly

Cleans with air and water.

Applications
Injection moldsDie-casting moldsAir coolersMold temperature controllers (MTC)ChillersAir compressorsInjection moldsDie-casting moldsAir coolersMold temperature controllers (MTC)ChillersAir compressors
Specifications

Four models, from 12 to 16+ circuits.

ModelTankPumpWater jointsSize (mm)WeightVoltage
K2-15CSingle, 50 L1.5 kW3/8" × 12, 1" × 21450 × 500 × 1050210 kgAC 220/380 V, 3-phase + E
K6-22CSingle or double, 100 L2.2 kW3/8" × 12, 1" × 21600 × 500 × 1200290 kgAC 220/380 V, 3-phase + E
K8-30CSingle or double, 150 L3.0 kW3/8" × 16, 1" × 2, 1.5" × 21700 × 600 × 1300360 kgAC 220/380 V, 3-phase + E
K8-55CSingle or double, 150 L5.5 kW3/8" × 16, 1" × 2, 2" × 21700 × 600 × 1300380 kgAC 220/380 V, 3-phase + E

Specifications subject to change.

FAQ

Frequently asked questions

Let’s engineer what’s next.

Tell us about your operation. We’ll reply with how software, robots or machinery can help — usually within one business day.